Hello! welcomeZhejiang Xikai Electric Co. , Ltd.
Zhejiang Xikai Electric Co. , Ltd.
Contact
Zhejiang Xikai Electric Co. , Ltd.
Mailbox:wzxikai@wzxikai.com
Tel:+86 577 61666 016
address:No.271, Weishiqi Road, Yueqing Economic Development Insuatrial Zone, Yueqing, Zhejiang.

product list

Indoor high voltage load switch
14/5000 Indoor vacuum circuit breaker
Outdoor vacuum circuit breaker
Outdoor high voltage load switch
Outdoor high voltage disconnector
Outdoor drop fuse
High voltage current limiting fuse series
High voltage complete set
current position:Home>Product Center

Product Center

    • FN16A Series Indoor Vacuum Load break Switch

    FN16A Series Indoor Vacuum Load break Switch

    FN16A indoor AC M.V Vacuum load break switch are developed by our company The products follow GB3804-90《3-62kV AC H.V load switch》and IEC62271《 AC H.V. indoor load break switch-fuse combinations》 (2002 edition). These switches are small volume, beautiful appearances, flexible installation, and easy operation. This switch applied for the 50/60Hz, 6-24kV Power distribution system. It can break on load current, and fuse combination can break the over load current and short circuit current. Load break switch with-fuse combinations are also used for protecting over load of transformer and avoiding short-circuit current.

    Technical Information

    Technical Specification

     

     

     

    Rated voltage

    kV

    12

    24

    Rated current

    A

    630

    630

    Rated power frequency

    Hz

    50/60

    50/60

    Short circuit making capacity

    kA Peak.

    50

    31.5

    Peak withstand current

    kA Peak.

    50

    50

    Short time current

    kA eff.

     

     

    1Sec.

     

    25

     

    3Sec.

     

    20

    20

    Max. breaking capacity in co-operation with fuses IEC 62271-105(IEC 420 1990-11)

    A

    2000

    2000

    Max. fuse current(XRNT Fuse)

    A

    200

    200

    Power frequency withstand voltage 50Hz 1 min,:

     

     

     

    - To earth and between poles

    kV

    42

    65

    - Across isolating distance

    kV

    48

    79

    Impulse withstand voltage 1.2/50μ s:

     

     

     

    - To earth and between poles

    kV

    75

    125

    - Across isolating distance

    kV

    85

    145

    Mechanism Endurance

     

     

     

    -Vauum interrupter

    cycles

    10000

    10000

    -Main switch and Earth Switch

    cycles

    2000

    2000


    Overall and installation dimensions